Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
Art.Nr.: 1117

M-Bond-610

  • Two-component, solvent-thinned, Epoxy-phenolic adhesive;
  • 1 bottle 30ml Curing Agentr;
  • 1 bottle 30ml Resin;
  • total weight 120 g

Widest Operating Temperature Range: -269° to +370°C.

WARNING - flammable product.

For security reasons, we can deliver this product ONLY within Germany.

All details
Artikelbeschreibung
  • Two-component, solvent-thinned, Epoxy-phenolic adhesive;
  • 1 bottle 30ml Curing Agentr;
  • 1 bottle 30ml Resin;
  • total weight 120 g

Widest Operating Temperature Range: -269° to +370°C.

WARNING - flammable product.

For security reasons, we can deliver this product ONLY within Germany.

Product description

Safety data sheets: https://www.micro-measurements.com/safety-data-sheets-sds

Two-component, solvent-diluted epoxy adhesive for the most demanding applications, including high-precision transducer construction. Its widest temperature range of any adhesive for general use. Its low viscosity allows for layer thicknesses of <0.005 mm. The extremely thin, hard, and bubble-free layers minimize creep, hysteresis, and linearity issues.
Curing must begin within 4 hours of application.

Klebstoff Characteristika

Temperature range:
Short-term: -269°C to +370°C.
Long-term: -269°C to +260°C.
Sensor: up to +230°C.
Expansion range:
1% at -269°C;
3% at +24°C;
3% at +260°C.
Storage time:
9 months at +24°C; 15 months at +5°C.
Pot life:
6 weeks at +24°C; 12 weeks at +5°C.
Contact pressure:
70 to 480 kN/m².
200 to 275 kN/m² optimum.

Curing time: e.g., 2 hours at 125°C to 1 hour at 175°C. Recommended: 2 hours at 135°C.

Recommended post-cure: 2 hours at 30 to 40°C above the maximum application temperature or cure temperature, whichever is higher.
Post-cure for high-precision transducers: 2 hours at +205 to +230°C after bridge wiring.

LatestProducts
Artikelbeschreibung
  • Two-component, solvent-thinned, Epoxy-phenolic adhesive;
  • 1 bottle 30ml Curing Agentr;
  • 1 bottle 30ml Resin;
  • total weight 120 g

Widest Operating Temperature Range: -269° to +370°C.

WARNING - flammable product.

For security reasons, we can deliver this product ONLY within Germany.

Product description

Safety data sheets: https://www.micro-measurements.com/safety-data-sheets-sds

Two-component, solvent-diluted epoxy adhesive for the most demanding applications, including high-precision transducer construction. Its widest temperature range of any adhesive for general use. Its low viscosity allows for layer thicknesses of <0.005 mm. The extremely thin, hard, and bubble-free layers minimize creep, hysteresis, and linearity issues.
Curing must begin within 4 hours of application.

Klebstoff Characteristika

Temperature range:
Short-term: -269°C to +370°C.
Long-term: -269°C to +260°C.
Sensor: up to +230°C.
Expansion range:
1% at -269°C;
3% at +24°C;
3% at +260°C.
Storage time:
9 months at +24°C; 15 months at +5°C.
Pot life:
6 weeks at +24°C; 12 weeks at +5°C.
Contact pressure:
70 to 480 kN/m².
200 to 275 kN/m² optimum.

Curing time: e.g., 2 hours at 125°C to 1 hour at 175°C. Recommended: 2 hours at 135°C.

Recommended post-cure: 2 hours at 30 to 40°C above the maximum application temperature or cure temperature, whichever is higher.
Post-cure for high-precision transducers: 2 hours at +205 to +230°C after bridge wiring.