Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
GSV-5A6 6-channel analog amplifier
GSV-5A6 6-channel analog amplifier
GSV-5A6 6-channel analog amplifier
GSV-5A6 6-channel analog amplifier
GSV-5A6 6-channel analog amplifier
GSV-5A6 6-channel analog amplifier
Art.Nr.: 14376

GSV-5A6 4-20-12/2k5/2

  • 6-channel strain gauge measuring amplifier
  • Aluminum housing, dimensions: 107 mm x 75 mm x 28 mm
  • 1 piece Sub-D44HD for connecting 6D Force-/Torque Sensors
  • 1x SUB-D15 socket for 6x analog output 4...20mA
  • 1x M8 round connector 4-pin for power supply, tare and shunt calibration
  • Analog output: 4...20mA
  • zero adjustment to 12mA
  • Cutoff frequency: 2.5kHz
  • Input sensitivity: 2mV/V
  • Supply voltage: 10V..28V DC
All details
Select variant:
Artikelbeschreibung
  • 6-channel strain gauge measuring amplifier
  • Aluminum housing, dimensions: 107 mm x 75 mm x 28 mm
  • 1 piece Sub-D44HD for connecting 6D Force-/Torque Sensors
  • 1x SUB-D15 socket for 6x analog output 4...20mA
  • 1x M8 round connector 4-pin for power supply, tare and shunt calibration
  • Analog output: 4...20mA
  • zero adjustment to 12mA
  • Cutoff frequency: 2.5kHz
  • Input sensitivity: 2mV/V
  • Supply voltage: 10V..28V DC
Highlights
  • 6-channels amplifier
  • analog output: 12 mA ±8 mA
  • Miniature aluminium housing 124 x 71,5 x 28 mm³
  • Zero setting function (set and reset)
  • Self-test function (shunt calibration)
Product description

The GSV-5A6 measuring amplifier is an amplifier with 6 independently configurable channels for strain gauge sensors, such as force sensors, torque sensors, acceleration sensors, or strain transducers.

Sensors are connected via a SubD44HD socket. Due to its compact dimensions and the SubD44HD socket, the measuring amplifier is ideal for connecting force/torque sensors and for mounting in close proximity to the sensor, e.g., on robot axis 3.

The output signals are connected to the SubD15 socket on the rear panel.

The 10 V DC...28 V DC power supply can be connected via the 4-pin M8 connector or the SubD15 socket on the rear panel. There are also two digital inputs with levels of 10...28 V for zeroing all output signals for shunt calibration.

The status after zeroing is permanently stored in an EEPROM of the measuring amplifier and remains intact even after a power interruption.

This measuring amplifier is suitable for connecting bridge sensors from 120 ohms to 5000 ohms or full-bridge strain gauges. Connection is possible using either a 4- or 6-wire connection. The sensor leads can be left open.

The GSV-5A6 measuring amplifier is supplied with an 18 V power supply and cables suitable for the Sub-D sockets.

The GSV-5A3 is operated and configured via a membrane keypad. The measuring range can be set in increments of 4.0, 2.0, 1.0, and 0.5 mV/V using the membrane keypad. Automatic zero signal adjustments can be triggered for the three channels. A self-test (shunt calibration) can be initiated. Locking is possible.

Recommended products
LatestProducts
GSV-5A6 4-20-12/2k5/2
GSV-5A6 4-20-12/2k5/2.pdf
GSV-5A6 4-20-12/2k5/2
GSV-5A6-step.zip
GSV-5A6 4-20-12/2k5/2
GSV-5A6-dimensions.pdf
GSV-5A6 4-20-12/2k5/2
BA_GSV5_A6_en.pdf
Artikelbeschreibung
  • 6-channel strain gauge measuring amplifier
  • Aluminum housing, dimensions: 107 mm x 75 mm x 28 mm
  • 1 piece Sub-D44HD for connecting 6D Force-/Torque Sensors
  • 1x SUB-D15 socket for 6x analog output 4...20mA
  • 1x M8 round connector 4-pin for power supply, tare and shunt calibration
  • Analog output: 4...20mA
  • zero adjustment to 12mA
  • Cutoff frequency: 2.5kHz
  • Input sensitivity: 2mV/V
  • Supply voltage: 10V..28V DC
Highlights
  • 6-channels amplifier
  • analog output: 12 mA ±8 mA
  • Miniature aluminium housing 124 x 71,5 x 28 mm³
  • Zero setting function (set and reset)
  • Self-test function (shunt calibration)
Product description

The GSV-5A6 measuring amplifier is an amplifier with 6 independently configurable channels for strain gauge sensors, such as force sensors, torque sensors, acceleration sensors, or strain transducers.

Sensors are connected via a SubD44HD socket. Due to its compact dimensions and the SubD44HD socket, the measuring amplifier is ideal for connecting force/torque sensors and for mounting in close proximity to the sensor, e.g., on robot axis 3.

The output signals are connected to the SubD15 socket on the rear panel.

The 10 V DC...28 V DC power supply can be connected via the 4-pin M8 connector or the SubD15 socket on the rear panel. There are also two digital inputs with levels of 10...28 V for zeroing all output signals for shunt calibration.

The status after zeroing is permanently stored in an EEPROM of the measuring amplifier and remains intact even after a power interruption.

This measuring amplifier is suitable for connecting bridge sensors from 120 ohms to 5000 ohms or full-bridge strain gauges. Connection is possible using either a 4- or 6-wire connection. The sensor leads can be left open.

The GSV-5A6 measuring amplifier is supplied with an 18 V power supply and cables suitable for the Sub-D sockets.

The GSV-5A3 is operated and configured via a membrane keypad. The measuring range can be set in increments of 4.0, 2.0, 1.0, and 0.5 mV/V using the membrane keypad. Automatic zero signal adjustments can be triggered for the three channels. A self-test (shunt calibration) can be initiated. Locking is possible.

Recommended products
LatestProducts
GSV-5A6 4-20-12/2k5/2
GSV-5A6 4-20-12/2k5/2.pdf
GSV-5A6 4-20-12/2k5/2
GSV-5A6-step.zip
GSV-5A6 4-20-12/2k5/2
GSV-5A6-dimensions.pdf
GSV-5A6 4-20-12/2k5/2
BA_GSV5_A6_en.pdf
GSV-5A6 4-20-12/2k5/2
bars-filter